CCTV Pipeline Inspection & Condition Assessment
NZ Lining provides CCTV pipeline surveys and condition assessments for stormwater, wastewater and pipeline rehabilitation projects. Using modern inspection equipment, our team can assess pipelines from 50 mm to 2000 mm in diameter, identify defects and provide accurate condition information to support maintenance and rehabilitation decisions.
Our operators work in accordance with New Zealand pipeline inspection standards, and where defects are identified, NZ Lining can also recommend suitable rehabilitation solutions.
Pipe Bursting
Pipe Bursting is an effective trenchless method to replace damaged or undersized sewer, water and gas lines.
This method requires minimal excavation and reinstatement at either end of the pipe section in addition to lateral or branch locations. Service connections are excavated, and the laterals are disconnected prior to starting the bursting process. This precautionary measure is to ensure that laterals are not damaged by the bursting process. A closed-circuit television (CCTV) inspection is carried out once the operation has been completed to confirm that no damages have been caused during this process.
Lateral Lining
Lateral Lining
Rehabilitation & Repair
Cured in Place Pipe Lining (CIPP)
The CIPP liner is designed according to the following factors:
+ Pipe condition, depth & ovality
+ Pipe Loading including traffic loading, hydrostatic loading
+ Chemical composition, and temperature of effluent, surrounding soil
Our key staff technical and field expertise and wide range of resources and equipment allow us to successfully tackle complicated and challenging projects on pipes ranging in diameter between 100mm to 1,500mm.
Factors taken into consideration when designing the liner and selecting the appropriate products and method include pipe condition, ovality, traffic and other live loading, pipe depth, water table level, chemical composition, and temperature of effluent, surrounding soil, site environmental sensitivity and impact on residents and public in the project area. Our key staff technical and field expertise and wide range of resources and equipment allow us to successfully tackle complicated and challenging projects on pipes ranging in diameter between 100mm to 1,500mm.Lateral Junction Repairs
The process involves installing a resin impregnated branched patch that is cured in place by ambient cure/heat or UV curing. The lateral junction repair (LJR) is compliant with the international standard ASTMF2561- 11. NZ Lining have the expertise and resources of serval LJR We have the capacity to install LJRs on pipe mains ranging in diameter between 150mm to 900mm.
The same trenchless process of Lateral Junction Repair is also used to seal the junction between a lateral pipe and a newly CIPP lined main to prevent water or roots coming through the lateral from going between the pipe and liner. NZ Lining have the expertise and resources of several LJR systems utilising ambient cure, heat cure and Ultraviolet cure lining techniques. We have the capacity to install LJRs on pipe mains ranging in diameter between 150mm to 900mm.
Lateral Lining
Our lateral lining service is compliant with the international standard ASTM F1216-16.
Manhole Rehabilitation
Depending on the existing substrate NZ Lining offer three different coating systems being:
+ Cementitious Coating
+ Epoxy Coating
+ Complete Manhole Lining
Our full service brochures